Boiler Water Test Kit

OverviewSpecificationsResources
For Low Pressure
Procedure:
To prevent corrosion and scaling in boiler water systems, it is essential to analyze both the natural impurities of the source water and the treated water characteristics.
Product Name
Method
Range
No. Of Tests
pH Strip 2.0-1.05 100 test
Total Hardness EDTA Titrimetry 1 - 25 ppm 100 tests
Total Alkalinity Acid-Base Titrimetry 5-500 ppm 100 tests
Chloride Argentometry 10 - 500 ppm 100 tests
Calcium EDTA Titrimetry 0 - 20 ppm 100 tests
Iron (Low range) 1,10-Phenanthroline 0 - 1 ppm 100 tests
Silica Photometric Hetro Poly Blue 0.1-1.2 mg/l 100 tests
Ortho phosphate Stannous Chloride 0 - 3 ppm 100 tests
Sulphite Iodometyry 0 - 500 mg/l 100 tests
Scope Of Supply:
pH Roll (2-10.5),100 ml of Hardness Buffer, pK/100 tablets Hardness indicator, 100 ml of Hardness reagent(or 50 ml of Hardness Buffer low, 10 ml of Hardness indicator, 100 ml of Hardness reagent low), pk/100 tablets Alkalinity indicator,100 ml alkalinity reagent, pk/100 chloride indicator, 100 ml of chloride reagent, 100 ml of calcium buffer. pK/100 calcium indicator, 100 ml of calcium reagent, 20 ml of phosphate reagent-1, 20 ml of phosphate reagent - 2,100 ml of Iron reagent-A, 40 ml of Iron reagent-B, 40 ml of Iron reagent-C, pk/ 100 pouches Residual chlorine reagent,Photo Meter, Silica Reagents, scissor,Test tube with cork-2 Nos, test tube stand, color chart for iron , phosphate and residual chlorine (DPD), measuring cylinder,plastic beaker, 100 ml conical flask, cleaning brush, board pin, instruction manual in a standard Z box.